Used CPAP Home About Us Used CPAP Accessories CPAP Sales masks Used CPAP Contact

Gently Used PR System One 60 Series Heated Humidifier with New Water Chamber

Part # DS6H, DS6TFLG

Product Information:

 

The Respironics PR System One 60 Series Heated Humidifier integrates with any 60 Series System One generation CPAP or BIPAP machine. The humidifier can operate in either manual, or automation mode, and is controlled by the connecting CPAP/VPAP device. Please keep in mind, that in order to use this heated humidifier in automated mode, you must have the thermal tubing, which is not sold with the heated humidifier but can be added at the bottom of this page. 

PLEASE verify that you model SYSTEM ONE is the correct one (60 Series) - to verify this, check the bottom of your CPAP or BIPAP machine for the reference number - that reference number would read one of the following: 260p, 460P, 560P, 660P, 760P, 960P, 1060P. The top of the 60 Series System One generation machines also have a silver-fleck are around the LCD screen; the System One 50 Series will have an off-white area around the LCD screen. The most important characteristic of the DS60 Series Heated Humidifier being sold here is that is has a 6-pin connector. That means that your CPAP or BIPAP machine must have a 6-pin female inlet, otherwise it will not fit. Any questions about this, please feel free to use the live chat on this page, or call our toll-free number at 855-263-2727.

Specifications on the Heated Humidifier

Material Components of Metal Plates on Humidifier and Inside Chamber: Anodized Aluminum

Temperature Operating: 41 F to 95 F (5 C to 35 C)

Temperature Storage: -4 F to 140 F (-20 C to 60 C)

Relative Humidity: 15 to 95% (non-condensing)

Atmospheric Pressure: 77 to 101 kPa (0 - 7500 ft.)

Dimensions: 7 in. L x 5.5 in. W x 4.0 in. H (18 x 14 x 10 cm)

Weight (with water tank empty): Approximately 1.95 lbs (<.89kg)

Water Capacity: 325 mL (1 1/3 cups /11 oz) at recommended water level

Standards Compliance: This humidifier is designed to conform to the following standards: IEC 60601-1 General Requirements for Safety of Medical Electrical Equipment EN ISO 8185 General Requirements for Humidification Systems

AC Power Consumption: (with 60 W power supply): 100 - 240 VAC, 50/60 Hz, 2.1 A max.

AC Power Consumption: (with 80 W power supply) 100 - 240 VAC, 50/60 Hz, 2.0 A max.

DC Power Consumption: 12 VDC, 6.67 A

Type of Protection Against Electric Shock: Class II Equipment

Degree of Protection Against Electric Shock: Type BF Applied Part

Equipment Type: IPX1: Drip Proof Equipment

Mode of Operation: Continuous

Electromagnetic Compatibility: The device meets the requirements of EN 60601-1-2, 2nd edition.

Heater Plate: 75 C (167 F)

System One Relative Humidity:

Setting 1 = 70%
Setting 2 = 80%
Setting 3 = 90%
Pressure Drop with Humidifier: (max.) 0.3cm H2O at 60 LPM flow
Humidity min Output: 10 mg H2O/L, measured at max flow, 35 C, 15% RH

Disposal: When necessary, dispose of the humidifier in accordance with local regulations.

Heated Tubing Specifications

Maximum Recommended Pressure: 25 cm H20

Inner Diameter: 15 mm (0.6 in.)

Length: 1.83 m (6 ft)

Heated Tubing Temperature Range: 16 to 32 C (60 to 89)

Heated Tubing Temperature Cut-out: ? 41 C (? 106 F)

Material: Flexible plastic and electrical components

Warranty Length: 6 Months

(Free Shipping within the US, no Sales Tax)


Gently Used Respironics PR System One 60 Series Heated Humidifier , with New Cleanable Water Chamber

$70.00

 

Add New System One Thermal Tubing with your System One 60 Series Heated Humidifier

$40.00

 

Return Policy

Copyright 2018, SecondwindCPAP LLC. All Rights Reserved. YOUR Used CPAP Specialists!